[MB-4940] default bucket is shutdown when run view test with 2 design docs more than 5 hours Created: 22/Mar/12  Updated: 03/Jul/12  Resolved: 31/May/12

Status: Closed
Project: Couchbase Server
Component/s: couchbase-bucket
Affects Version/s: 2.0-developer-preview-4
Fix Version/s: 2.0-beta
Security Level: Public

Type: Bug Priority: Major
Reporter: Thuan Nguyen Assignee: Thuan Nguyen
Resolution: Incomplete Votes: 0
Labels: 2.0-dev-preview-4-release-notes
Remaining Estimate: Not Specified
Time Spent: Not Specified
Original Estimate: Not Specified
Environment: windows 2008 R2 64 bit

Attachments: GZip Archive 10.1.1.173-8091-diag.txt.gz     GZip Archive 10.1.1.174-8091-diag.txt.gz     GZip Archive 10.1.1.176-8091-diag.txt.gz    

 Description   
Install couchbase server 2.0.0dp4r-724 on 3 windows 2008 R2 64bit.
Create cluster with 3 nodes.
Create default bucket
Run mcsoda to load 5 million items
Run view with 2 design docs (10 view per design docs).
Let mcsoda and view run over 5 hours
See on node down in cluster.
Look at log, see error
     Shutting down bucket "default" on 'ns_1@10.1.1.176' for server shutdown

 Comments   
Comment by Steve Yen [ 08/May/12 ]
Hi Thuan,

Has QE seen cases like this for linux? That would help to know whether this is windows-specific or ns_server or something else.
Comment by Chiyoung Seo [ 31/May/12 ]
The bug title and message is not clear to me. In addition, there have been lots of fixes and changes since DP4 release. Please reopen it when you see this issue with the latest 2.0 build.
Generated at Fri Aug 22 10:06:47 CDT 2014 using JIRA 5.2.4#845-sha1:c9f4cc41abe72fb236945343a1f485c2c844dac9.