Details
-
Type:
Bug
-
Status:
Closed
-
Priority:
Major
-
Resolution: Fixed
-
Affects Version/s: 1.0.2
-
Fix Version/s: 1.0.4
-
Component/s: library
-
Security Level: Public
-
Labels:
-
Environment:Centos5x OR Ubuntu 11x running Couchbase 1.8.0. 3 Node Cluster, plenty of available RAM and DISK. PHP 5.3. libcouchbase version 1.0.3-1
Description
This bug is reported by a customer. Whenever they issue a rebalance(after removing a node from the cluster or add a new node), client operations(PHP - sample code attached) time out with the error below
PHP Warning: Couchbase::set(): Failed to store a value to server: Operation timed out in /root/test_worker.php on line <n>
This issue is consistent for both the customer as well as our in-house reproduction in Support. There are no errors on the server side. Rebalance does complete. And once rebalance is complete, the same script runs fine without any errors.
PHP Warning: Couchbase::set(): Failed to store a value to server: Operation timed out in /root/test_worker.php on line <n>
This issue is consistent for both the customer as well as our in-house reproduction in Support. There are no errors on the server side. Rebalance does complete. And once rebalance is complete, the same script runs fine without any errors.